> Design
and Construction > Automatic
Activation Devices and Reserve Static Lines > Reserve
Static Line Systems > Ripcord Cable Routing
The routing of the ripcord cable from the handle
to the pin determines where the lanyard connects to the cable.
Most RSL attachments connect with the ripcord cable either at
the yoke area or just above the ripcord pin. Generally, there
is a double ring installation where the cable end of the lanyard
is located. [Figure 2-53] On this particular installation, the
connection is at the shoulder yoke area.

Figure 2-53. Double ring container
installation
|